APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black

Brand: Apc · SKU: AP7922B · MPN: AP7922B · Category: Data Center

APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black
Request for Quote
In Stock • 150 units

APC AP7922B, Metered, Switched, 2U, Single-phase, Horizontal, Black, 16 AC outlet(s). APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black (part number AP7922B) is an enterprise pdus product available from Server Tech Central. Key specifications include type Single-phase, depth 114 mm, width 445 mm, height 89 mm, weight 4.5 kg, mounting Horizontal, pdu types Metered, Switched, monitoring Current, Power, Voltage. Every unit is fully tested and backed by our standard 3-Year Warranty, with free US ground shipping and same-day dispatch on in-stock orders. Volume pricing and Net-30 terms are available for qualified businesses, government, and education.

Specifications

TypeSingle-phase
Depth114 mm
Width445 mm
Height89 mm
Weight4.5 kg
MountingHorizontal
PDU typesMetered, Switched
MonitoringCurrent, Power, Voltage
Power plugIEC309
Cable length3.05 m
CertificationCE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
Load capacity7360 VA
Maximum power7360 W
Package depth368 mm
Package width508 mm
Rack capacity2U
Outlet controlLock-out, Recycle, Turn off, Turn on
Package height140 mm
Package weight6.55 kg
Product colourBlack
AC outlet typesC13 coupler
Maximum current32 A
Packaging contentDocumentation CD, Installation Guide, Rack Mounting Brackets
AC input frequency50 - 60 Hz
Warranty3-Year Warranty
Weight4.5 kg
Dimensions445 mm x 114 mm x 89 mm

Product Description

Availability Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability) Marketing Features Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. Agility Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Key Features

APC AP7922B. PDU types: Metered, Switched, Rack capacity: 2U, Type: Single-phase. AC outlets quantity: 16 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC309. Cable length: 3.05 m. Monitoring: Current, Power, Voltage, Outlet control: Lock-out, Recycle, Turn off, Turn on. Nominal input voltage: 200-230 V, Maximum current: 32 A, AC input frequency: 50 - 60 Hz

Frequently Asked Questions

Is this product genuine OEM?

Yes, this APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black (AP7922B) is 100% genuine Apc hardware. All our products are verified by certified technicians and come with clean serial numbers ready for service contract registration.

What warranty is included?

This APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black includes our standard 3-Year Warranty covering all manufacturing defects. We also offer advanced replacement options for minimal downtime.

How long does shipping take?

We offer free ground shipping which typically takes 3-5 business days. Expedited shipping options are available at checkout for faster delivery.

Can I return this product?

Yes, we have a 30-day return policy on all products. Restocking fees may apply for opened items. Please see our return policy for complete details.

Is the APC AP7922B power distribution unit (PDU) 16 AC outlet(s) 2U Black compatible with my system?

Please check the specifications tab for detailed compatibility information. Our technical team is available to assist with compatibility questions for the AP7922B.

More in Data Center

Explore Related Categories